Safety Rubber Mats For Electrical Applications!

Frequently called protected floor covers, electrical flourishing matting safeguards people working close to electrical establishments from electric shocks, and should agree with Electrical Insulation Matting since Rubber Matting was not adequate to guard laborers.


A security mat is a chief piece of an electrical flourishing system, normally utilized around regions containing high voltage (HV) gear, like a switchboard. In any case, thriving mats are additionally accessible to chip away at low and medium-voltage (LV and MV) gear.

The normal utilization of this wary stuff worked before switchboards, control gear, in plant rooms and lift control rooms, what's more as versatile security with live hardware during site arranging works out.


An association's wagered evaluation ought to focus on any conceivable shock prospects, and electrical success mats are suggested in the HSE's Safe Working Practices for Electricity at Work report, HSG85, explicitly under Electrical Insulation (Live to work. Electrical protecting mat UK Standards Institution). As well as foiling ground contact through the floors, it besides assists with giving protection.


As a part of its suggestions, the HSE supports giving shielded matting to deal with electrical flourishing while at the same time welding and remembering that working gear in quarries, improvement regions, and other relative conditions.

Take care while going with a decision


In the improvement of electrical security mats and Outdoor Matting, express voltage for the degree of hazard is endeavored to guarantee that the mat can overcome the voltage of the stuff that is being gotten to. Hence, it is fundamental that sufficient cautious advances are taken so the fitting degree of affirmation can be supervised while working with electrical stuff.

As well as meeting additional specific basics not framed in the UK standard, electrical security materials should besides meet a ton of different necessities that guarantee life range in unforgiving conditions.

The separation between BS EN 61111:2009 and BS 921:1976

Because of its inability to meet the necessities spread out by the Working Group, BS 921:1976 was dispensed with and a pristine standard was fanned out, BS EN 61111:2009, which is the new open norm for electrical protecting mats. To meet the necessities of BS EN 61111:2009, the mat should complete a more vital number of evaluations than those ordinary by BS 921:1976. Various degrees of voltage are organized and each class has a particular security class given out to it. Furthermore, it concludes a most ludicrous thickness of material expected to accomplish this stood apart from a base thickness depicted inside BS921:1976, and as such endeavors to guarantee a raised level of the material game plan. Plus, each meter of Rubber Matting Rolls is combination coded and forever put aside on the opposite to obviously see the degree of security, it gives, guaranteeing both right use and full detectable quality back to the designer.


The BS EN 61111:2009 standard recommends that all mats inside classes 1 to 4 reviewing those for gathering, be endeavored at standard ranges. For Class 0, a visual review might be palatable; in any case, a standard dielectric test as per EN 6111:2009 might be referred to and is suggested by the maker.

Makers are in addition expected to test the material against the going with models as per the BS EN 61111 detail:

- The mechanical protection from invaders

- Protection from oil

- Protection from disastrous

- Protection from slippage

- The capacity to conflict with fire

- The creation system

- The strength of markings

Moreover, conformance with BS EN 61111:2009 recommends that the matting will enjoy different upper hands over BS 921: 1976, as it is oil and disastrous safe, heatproof, lighter in weight, and there are various classes for various voltage applications.

BS 921: 1976, which has been supplanted, is as of now open, everything being equal as of now reasonable for its clever clarification in the UK. New applications and establishments ought to, regardless, exhibit BS EN 61111, and perceive the right grade for the voltage utilized.